BuildCodes.ca
8.15 articles · 3 subsections

General

8.1.1

Scope

8.1.1.1

Scope

(1)The scope of this Part shall be as described in Subsection 1.3.3. of Division A.

8.1.1.2

Definitions

(1)Except as provided in Sentence (2), words that appear in italics are defined in Article 1.4.1.2. of Division A and in the Building Code Act, 1992.

(2)In this Part, Soil means in-situ, naturally occurring, unconsolidated mineral or organic material, at the earth's surface that is at least 100 mm thick and capable of supporting plant growth, and includes material compacted or cemented by soil forming processes, but does not include displaced materials such as gravel dumps, mine spoils, or like deposits.

8.1.2

Application

8.1.2.1

Classification of Systems

(1)All sewage systems shall be classed as one of the following:

  • (a) Class 1 — a chemical toilet, an incinerating toilet, a recirculating toilet, a self-contained portable toilet and all forms of privy including a portable privy, an earth pit privy, a pail privy, a privy vault and a composting toilet system,
  • (b) Class 2 — a greywater system,
  • (c) Class 3 — a cesspool,
  • (d) Class 4 — a leaching bed system, or
  • (e) Class 5 — a system that requires or uses a holding tank for the retention of hauled sewage at the site where it is produced prior to its collection by a hauled sewage system.
8.1.2.2

Operation and Maintenance

(1)Operation and maintenance of sewage systems shall comply with Section 8.9.

8.1.3

Limitations

8.1.3.1

Discharge

(1)Except as provided in Sentences (2) to (6), the sewage system shall be designed and constructed to receive only sanitary sewage of domestic origin.